CONSIDERATION ON THE ROLE VENTILATION AND AIR CONDITIONING SYSTEMS DURING COVID-19 TIMES: SOURCE CONTROL, VENTILATION, AIR DISTRIBUTION

Paul Alexandru Danca, Ilinca Nastase, Mihnea Sandu, Matei Georgescu, Cristiana Croitoru

First published: 2023https://doi.org/10.35603/sws.iscss.2023/s13.53View metrics

Abstract

Due to the undergoing pandemic the advanced ventilation strategies should be further developed, aiming at reducing cross infection risk and combining the consideration of thermal comfort and energy saving. Besides air dilution methods, other distribution schemes relying on transport of pollutants and the protection of the breathing zone should be considered and current standards must be improved to explicitly consider infection control. In the same time, we must not forget that the use of monitors displaying the state of indoor air quality could be a good indicator of enough ventilation rate. The scope of this paper is to analyze the current and major issues related to COVID-19 and to argue some strategies and best practices regarding indoor air and mechanical ventilation, as well as HVAC systems operation.

Publication Impact Profile

PlumX
  • Captures
  • Mendeley - Readers: 2

Publication details

Title
CONSIDERATION ON THE ROLE VENTILATION AND AIR CONDITIONING SYSTEMS DURING COVID-19 TIMES: SOURCE CONTROL, VENTILATION, AIR DISTRIBUTION
Authors
Paul Alexandru Danca, Ilinca Nastase, Mihnea Sandu, Matei Georgescu, Cristiana Croitoru
Proceedings
Proceedings of 10th SWS International Scientific Conference on Social Sciences - ISCSS 2023
Publisher
SGEM WORLD SCIENCE (SWS) Scholarly Society
Year
2023
Pages
707-722
SWS Citekey
Danca202313111
ISSN
2682-9959
ISBN
978-3-903438-06-4
Language
en
Publication type
Proceedings Paper
Keywords
References53
  1. ASHRAE Position Document on Airborne Infectious Diseases. 2020. https://www.ashrae.org/file%20library/about/position%20documents/airborneinfectious- diseases.pdf. 2020.

  2. Xu, C., et al., Effects of personalized ventilation interventions on airborne infection risk and transmission between occupants. Building and Environment, 2020: p. 107008.

  3. Aliabadi, A.A., et al., Preventing airborne disease transmission: review of methods for ventilation design in health care facilities. Advances in preventive medicine, 2011.

  4. Greenhalgh, T., et al., Ten scientific reasons in support of airborne transmission of SARS-CoV-2. The Lancet, 2021. 397(10285): p. 1603-1605.

  5. Wei, J. and Y. Li, Airborne spread of infectious agents in the indoor environment. American Journal of Infection Control, 2016. 44(9): p. S102-S108.

  6. Role of ventilation in airborne transmission of infectious agents in the built environment – a multidisciplinary systematic review. Indoor Air, 2007. 17(1): p. 2-18.

  7. Luongo, J.C., et al., Role of mechanical ventilation in the airborne transmission of infectious agents in buildings. Indoor Air, 2016. 26(5): p. 666-678.

  8. Zhang, N., et al., Most self-touches are with the nondominant hand. Scientific Reports, 2020. 10(1): p. 10457.

  9. Morawska L., J.G., Ristovski Z., Hargreaves M., Mengersen K., Corbett S. , Size distribution and sites of origin of droplets expelled from the human respiratory tract during expiratory activities. J. Aerosol Sci., 2009(40): p. 256-259.

  10. Morawska, L., et al., Size distribution and sites of origin of droplets expelled from the human respiratory tract during expiratory activities. Journal of Aerosol Science, 2009. 40(3): p. 256-269.

  11. Sterling EM, Arundel A, and Sterling TD, Criteria for Human Exposure to Humidity in Occupied Buildings. ASHRAE Transactions, 1985. 91(1): p. CH85-13.

  12. Metz, J.A. and A. Finn, Influenza and humidity--Why a bit more damp may be good for you! J Infect, 2015. 71 Suppl 1: p. S54-8.

  13. Shao, S., et al., Risk assessment of airborne transmission of COVID-19 by asymptomatic individuals under different practical settings. Journal of Aerosol Science, 2021. 151: p. 105661.

  14. Bourouiba, L., Turbulent Gas Clouds and Respiratory Pathogen Emissions: Potential Implications for Reducing Transmission of COVID-19. JAMA, 2020. 323(18): p. 1837-1838.

  15. Jayaweera, M., et al., Transmission of COVID-19 virus by droplets and aerosols: A critical review on the unresolved dichotomy. Environmental Research, 2020. 188: p. 109819.

  16. Abkarian, M., et al., Speech can produce jet-like transport relevant to asymptomatic spreading of virus. Proceedings of the National Academy of Sciences, 2020. 117(41): p. 25237-25245.

  17. Tang, J.W., et al., A schlieren optical study of the human cough with and without wearing masks for aerosol infection control. Journal of The Royal Society Interface, 2009. 6(suppl_6): p. S727-S736.

  18. Web site https://www.projectmask.nl/testing/carbon-dioxide/procedure. 2020.

  19. Zhang, X., et al., Investigation of the flow-field in the upper respiratory system when wearing N95 filtering facepiece respirator. Journal of Occupational and Environmental Hygiene, 2016. 13(5): p. 372-382.

  20. REHVA. REHVA COVID 19 Guidance https://www.rehva.eu/activities/covid-19- guidance/rehva-covid-19-guidance. 2020.

  21. Buonanno, G., L. Stabile, and L. Morawska, Estimation of airborne viral emission: Quanta emission rate of SARS-CoV-2 for infection risk assessment. Environment International, 2020. 141.

  22. Kurnitski, J. https://www.rehva.eu/covid19-ventilation-calculator. 2020.

  23. Miller, S.L., et al., Transmission of SARS-CoV-2 by inhalation of respiratory aerosol in the Skagit Valley Chorale superspreading event. Indoor Air, 2021. 31(2): p. 314-323.

  24. Morawska, L., et al., How can airborne transmission of COVID-19 indoors be minimised? Environment International, 2020. 142: p. 105832.

  25. Buonanno, G., L. Morawska, and L. Stabile, Quantitative assessment of the risk of airborne transmission of SARS-CoV-2 infection: Prospective and retrospective applications. Environment International, 2020. 145: p. 106112.

  26. Rajaratnam, N., Turbulent jets. 1976, Amsterdam, Netherlands: Elsevier Scientific Publishing Company.

  27. Alsaad, H. and C. Voelker, Qualitative evaluation of the flow supplied by personalized ventilation using schlieren imaging and thermography. Building and Environment, 2020. 167: p. 106450.

  28. Xu, C. and L. Liu, Personalized ventilation: One possible solution for airborne infection control in highly occupied space? Indoor and Built Environment, 2018. 27(7): p. 873-876.

  29. Sun, W., et al., Thermal performance of a personalized ventilation air terminal device at two different turbulence intensities. Building and environment, 2007. 42: p. 3974-3983.

  30. Gao, N. and J. Niu, CFD study on micro-environment around human body and personalized ventilation. Building and Environment, 2004. 39 p. 795 - 805.

  31. Georgescu, M.R., et al., Personalized ventilation solutions for reducing CO2 levels in the crew quarters of the International Space Station. Building and Environment, 2021. 204: p. 108150.

  32. Danca, P., et al., Personalized Ventilation as a Possible Strategy for Reducing Airborne Infectious Disease Transmission on Commercial Aircraft. Applied Sciences, 2022. 12(4).

  33. Pantelic, J., et al., Personalized ventilation as a control measure for airborne transmissible disease spread. J R Soc Interface, 2009. 6 Suppl 6(Suppl 6): p. S715-26.

  34. ISO 18158 - Workplace air — Terminology. 2016.

  35. Georgescu, M.R., A. Meslem, and I. Nastase, Accumulation and spatial distribution of CO2 in the astronaut's crew quarters on the International Space Station. Building and Environment, 2020. 185: p. 107278.

  36. Tasdemiroglu, E., F.R. Berjano, and D. Tinaut, The performance results of Trombe-Wall passive systems under Aegean Sea climatic conditions. Solar Energy, 1983. 30(2): p. 181-189.

  37. Mansour, A.R., J. Bassam Ali, and B. Tashtoush, An approximate analytical solution to convective laminar heat transfer flow within the trombe wall channel. International Communications in Heat and Mass Transfer, 1991. 18(1): p. 153-159.

  38. Melikov, A.K., Personalized ventilation. Indoor Air Pollution, 2004. 14(suppl. 7): p. 157-167.

  39. Melikov, A., T. Ivanova, and G. Stefanova, Seat headrest-incorporated personalized ventilation: Thermal comfort and inhaled air quality. Building and Environment, 2012. 47(0): p. 100-108.

  40. Khalifa, E.H., M.I. Janos, and D.J. F., Experimental investigation of reducedmixing personal ventilation jets. Building and environment, 2009. 44(8): p. 1551-1558

  41. Schiavon, S., A.K. Melikov, and C. Sekhar, Energy analysis of the personalized ventilation system in hot and humid climates. Energy and Buildings, 2010. 42(5): p. 699-707.

  42. Russo, J.S., T.Q. Dang, and H.E. Khalifa, Computational analysis of reducedmixing personal ventilation jets. Building and Environment, 2009. 44(8): p. 1559-1567.

  43. Melikov, A.K., R. Cermak, and M. Majer, Personalized ventilation: evaluation of different air terminal devices. Energy and Buildings, 2002. 34(8): p. 829-836.

  44. Meslem, A., M. El-Hassan, and I. Nastase, Analysis of jet entrainment mechanism in the transitional regime by time-resolved PIV. Journal of Visualization, 2010. 14(1): p. 41-52.

  45. Meslem, A., I. Nastase, and F. Allard, Passive mixing control for innovative air diffusion terminal devices for buildings. Building and Environment, 2010. 45 ( 2679- 2688).

  46. Nastase, I., Analyse des jets lobes en vue de leur integration dans les Unites Terminales de Diffusion d'air. 2007, Universite de La Rochelle: Ph.D. Thesis.

  47. Nastase, I. and A. Meslem, Vortex dynamics and entrainment mechanisms in low Reynolds orifice jets. Journal of Visualization, 2008. 11(4).

  48. Nastase, I. and A. Meslem, Vortex dynamics and mass entrainement in turbulent lobed jets with and without lobe deflection angles. Experiments in Fluids, 2010. 48(4): p. 693-714.

  49. Nastase, I., A. Meslem, and P. Gervais, Primary and secondary vortical structures contribution in the entrainement of low Reynolds number jet flows. Experiments in Fluids, 2008. 44(6): p. 1027-1033.

  50. Nastase, I., et al., Lobed grilles for high mixing ventilation - An experimental analysis in a full scale model room. Building and Environment, 2011. 46( 3): p. 547- 555.

  51. Kristiawan, M., et al., Wall shear rates and mass transfer in impinging jets: Comparison of circular convergent and cross-shaped orifice nozzles. International Journal of Heat and Mass Transfer, 2012. 55(1-3): p. 282-293.

  52. Akbarzadeh, A., W.W.S. Charters, and D.A. Lesslie, Thermocirculation characteristics of a Trombe wall passive test cell. Solar Energy, 1982. 28(6): p. 461- 468.

  53. Lungu, C.I. and I. Nastase, Brief overview on the UVGI disinfection technology. Revista Romana de Inginerie Civila, 2021. 12(2): p. 207-227.

View or Download full articleAccess options
Full paper accessChoose SWS login, librarian support, or instant article download.

SWS access login

Login as SWS Scientific Committee

Authors and approved SWS contributors will read and export their own linked papers after identity matching by SWS profile, email and SGEM GlobalID.

For librarian assistance: [email protected]

Purchase Instant Access

48-hour online accessComing soon
Online-only accessComing soon
Download the full article in PDF formatEUR 35
  • Article can be downloaded after successful payment.
  • Article may be used according to SWS library access terms.
  • Article cannot be redistributed.
Get full paper

Back to publication list